]> Creatis software - gdcm.git/blobdiff - Dicts/README
Modify TestValidate to compile with New() vs new
[gdcm.git] / Dicts / README
index cfaf066a547df9bfaf907da77b940af9ed93ed2a..6f94c6ec9985c35738f491459d24021208dc7df1 100644 (file)
@@ -106,6 +106,7 @@ http://www.gehealthcare.com/euen/interoperability/docs/2288567_100r3_0.pdf
 
 I was searching for 0043 1039, I could only find:
 http://www.gehealthcare.com/it_solutions/connectivity/pdf/hispeed_np.pdf
+ok -> http://www.gehealthcare.com/usen/interoperability/dicom/docs/hispeed_np.pdf
 but the link points nowhere, the document describes:
 HiSpeed LX/i, FX/i, DX/i, DX/iB 2.00/2.01/2.02 CONFORMANCE STATEMENT for DICOM v3.0
 
@@ -113,12 +114,15 @@ HiSpeed LX/i, FX/i, DX/i, DX/iB 2.00/2.01/2.02 CONFORMANCE STATEMENT for DICOM v
 
 
 0043 1060 was found at: http://www.gehealthcare.com/it_solutions/connectivity/pdf/2246181r25.pdf
+ok -> http://www.gehealthcare.com/usen/interoperability/dicom/docs/2246181r25.pdf
 0043 1060 IS 8 slop_int_10...slop_int_17
 
 I would also need:
 Signa Horizon Lx DICOM CONFORMANCE STATEMENT for DICOM v3.0
 grrrr: Vas flags 0043 1032 SS 1 in http://www.vitalcom.com/it_solutions/connectivity/pdf/2317752r3.pdf
+ok: -> www.gehealthcare.com/usen/interoperability/dicom/docs/2317752r3.pdf
 but 0043 1032 SS 1 Raw data type http://www.vitalcom.com/it_solutions/connectivity/pdf/2171143r25.pdf
+ok -> www.gehealthcare.com/usen/interoperability/dicom/docs/2171143r25.pdf
 
 Adding a page from : http://www.vitalcom.com/it_solutions/connectivity/pdf/2317752r3.pdf
  
@@ -201,6 +205,7 @@ Scanner Table Entry + Gradient Coil Selected (0043,106f) DS 3 or 4
 Notes from:
 PathSpeedtm PACS Version 8.0 CONFORMANCE STATEMENT for DICOM V3.0
 http://www.gehealthcare.com/it_solutions/connectivity/pdf/iis_fp_10282r1.pdf
+ok -> www.gehealthcare.com/usen/interoperability/dicom/docs/iis_fp_10282r1.pdf
 
 See GE_ImageThumbnails
 --------------------------------------------------
@@ -276,6 +281,7 @@ http://www.gehealthcare.com/usen/interoperability/dicom/docs/2261302_100r1.pdf
 For GEMS-Advantx.dic
 [EchoPAC PC version 4 CONFORMANCE STATEMENT for DICOM]
 http://www.gehealthcare.com/it_solutions/connectivity/pdf/EP250409r06.pdf
+ok -> www.gehealthcare.com/usen/interoperability/dicom/docs/EP250409r06.pdf
 http://www.gehealthcare.com/usen/xr/dicom/docs/2142506_100r01_ps.pdf
 
 
@@ -296,3 +302,20 @@ SPI.dic and SIEMENS.dic were generated based on D. Clunie work at:
 http://www.dclunie.com/medical-image-faq/html/part4.html
 
 and spi.tpl siemens.tpl from dicom3tools (20050611 snapshot)
+
+
+---------------------------------------------------
+
+Alright SIEMENS is totally screwed up...
+Let's have a look at:
+[Aristos VB10]
+http://www.medical.siemens.com/siemens/en_INT/rg_marcom_FBAs/files/brochures/DICOM/ax/Aristos_DicomConformanceStatement.pdf
+
+SOMATOM syngo VA50A DICOM Conformance Statement
+http://61.62.116.208/webhd/adams/LinkedDocuments/SENSATION_16.pdf
+
+SOMATOM syngo VA45A DICOM Conformance Statement
+http://61.62.116.208/webhd/adams/LinkedDocuments/EMOTION%206%20DICOM.pdf
+
+Somaris/5 VA70A CT DICOM Conformance Statement
+http://www.petscaninfo.com/zportal/portals/ctimi/prodandserv/dicom_statements/xvi.pdf