From 78de8596524234f23c96c2cbb829ac74f173e958 Mon Sep 17 00:00:00 2001 From: malaterre Date: Fri, 11 Nov 2005 22:31:39 +0000 Subject: [PATCH] ENH: Tons of fix: - SQ not declared as SQ - Regular Element declared as SQ - Element not retired - Element missing - Waveform problem rappear (I swear I clean them already) the 50/60 needs to be update to propagate the RET thing... too lazy to do it. - Update some name (missing s, missing Overlay...) - DS declared as CS, vice versa... --- Dicts/dicomV3.dic | 170 +++++++++++++++++++++++----------------------- 1 file changed, 85 insertions(+), 85 deletions(-) diff --git a/Dicts/dicomV3.dic b/Dicts/dicomV3.dic index bd2e3846..ba05ce67 100644 --- a/Dicts/dicomV3.dic +++ b/Dicts/dicomV3.dic @@ -68,7 +68,7 @@ 0008 0016 UI 1 SOP Class UID 0008 0018 UI 1 SOP Instance UID 0008 001a UI 1-n Related General SOP Class UID -0008 001b UI 1-n Original Specialized SOP Class UID +0008 001b UI 1 Original Specialized SOP Class UID 0008 0020 DA 1 Study Date 0008 0021 DA 1 Series Date 0008 0022 DA 1 Acquisition Date @@ -119,7 +119,7 @@ 0008 0114 ST 1 Coding Scheme External ID 0008 0115 ST 1 Coding Scheme Name 0008 0116 ST 1 Responsible Organization -0008 0201 SH 1 Timezone Offset From UTC +0008 0201 SH 1 Timezone Offset From UTC 0008 1000 LT 1 Network ID (RET) 0008 1010 SH 1 Station Name 0008 1030 LO 1 Study Description @@ -147,9 +147,7 @@ 0008 113a SQ 1 Referenced Waveform Sequence 0008 1140 SQ 1 Referenced Image Sequence 0008 1145 SQ 1 Referenced Curve Sequence -0008 1148 SQ 1 Referenced Previous Waveform -0008 114a SQ 1 Referenced Simultaneous Waveforms -0008 114c SQ 1 Referenced Subsequent Waveform +0008 114a SQ 1 Referenced Instance Sequence 0008 1150 UI 1 Referenced SOP Class UID 0008 1155 UI 1 Referenced SOP Instance UID 0008 115a UI 1-n SOP Classes Supported @@ -372,7 +370,7 @@ 0018 1136 DS 1-n Table Lateral Increment 0018 1137 DS 1-n Table Longitudinal Increment 0018 1138 DS 1 Table Angle -0018 113a DS 1 Table Type +0018 113a CS 1 Table Type 0018 1140 CS 1 Rotation Direction 0018 1141 DS 1 Angular Position 0018 1142 DS 1-n Radial Position @@ -423,7 +421,7 @@ 0018 1310 US 4 Acquisition Matrix 0018 1312 CS 1 In-plane Phase Encoding Direction 0018 1314 DS 1 Flip Angle -0018 1315 CS 1 Variable Flip Angle +0018 1315 CS 1 Variable Flip Angle Flag 0018 1316 DS 1 SAR 0018 1318 DS 1 dB/dt 0018 1400 LO 1 Acquisition Device Processing Description @@ -432,7 +430,7 @@ 0018 1403 CS 1 Cassette Size 0018 1404 US 1 Exposures on Plate 0018 1405 IS 1 Relative X-ray Exposure -0018 1450 CS 1 Column Angulation +0018 1450 DS 1 Column Angulation 0018 1460 DS 1 Tomo Layer Height 0018 1470 DS 1 Tomo Angle 0018 1480 DS 1 Tomo Time @@ -495,7 +493,7 @@ 0018 5026 DS 1 Cranial Thermal Index 0018 5027 DS 1 Soft Tissue Thermal Index 0018 5028 DS 1 Soft Tissue-focus Thermal Index -0018 5029 CS 1 Soft Tissue-surface Thermal Index +0018 5029 DS 1 Soft Tissue-surface Thermal Index 0018 5030 DS 1 Dynamic Range (RET) 0018 5040 DS 1 Total Gain (RET) 0018 5050 IS 1 Depth of Scan Field @@ -505,16 +503,16 @@ 0018 5210 DS 6 Image Transformation Matrix (RET) 0018 5212 DS 3 Image Translation Vector (RET) 0018 6000 DS 1 Sensitivity -0018 6011 SQ 1 Sequence of Ultrasound Regions +0018 6011 SQ 1 Sequence of Ultrasound Regions 0018 6012 US 1 Region Spatial Format 0018 6014 US 1 Region Data Type 0018 6016 UL 1 Region Flags -0018 6018 UL 1 Region Location Min X(0) -0018 601a UL 1 Region Location Min Y(0) -0018 601c UL 1 Region Location Max X(1) -0018 601e UL 1 Region Location Max Y(1) -0018 6020 SL 1 Reference Pixel X(0) -0018 6022 SL 1 Reference Pixel Y(0) +0018 6018 UL 1 Region Location Min X0 +0018 601a UL 1 Region Location Min Y0 +0018 601c UL 1 Region Location Max X1 +0018 601e UL 1 Region Location Max Y1 +0018 6020 SL 1 Reference Pixel X0 +0018 6022 SL 1 Reference Pixel Y0 0018 6024 US 1 Physical Units X Direction 0018 6026 US 1 Physical Units Y Direction 0018 6028 FD 1 Reference Pixel Physical Value X @@ -530,14 +528,14 @@ 0018 6039 SL 1 Doppler Sample Volume X Position 0018 603a UL 1 Doppler Sample Volume Y Position (RET) 0018 603b SL 1 Doppler Sample Volume Y Position -0018 603c UL 1 TM-Line Position X(0) (RET) -0018 603d SL 1 TM-Line Position X(0) -0018 603e UL 1 TM-Line Position Y(0) (RET) -0018 603f SL 1 TM-Line Position Y(0) -0018 6040 UL 1 TM-Line Position X(1) (RET) -0018 6041 SL 1 TM-Line Position X(1) -0018 6042 UL 1 TM-Line Position Y(1) (RET) -0018 6043 SL 1 TM-Line Position Y(1) +0018 603c UL 1 TM-Line Position X0 (RET) +0018 603d SL 1 TM-Line Position X0 +0018 603e UL 1 TM-Line Position Y0 (RET) +0018 603f SL 1 TM-Line Position Y0 +0018 6040 UL 1 TM-Line Position X1 (RET) +0018 6041 SL 1 TM-Line Position X1 +0018 6042 UL 1 TM-Line Position Y1 (RET) +0018 6043 SL 1 TM-Line Position Y1 0018 6044 US 1 Pixel Component Organization 0018 6046 UL 1 Pixel Component Mask 0018 6048 UL 1 Pixel Component Range Start @@ -615,6 +613,7 @@ 0018 9027 CS 1 Spatial Pre-saturation 0018 9028 CS 1 Tagging 0018 9029 CS 1 Oversampling Phase +0018 9022 CS 1 Blood Signal Nulling 0018 9030 FD 1 Tag Spacing First Dimension 0018 9032 CS 1 Geometry of k-Space Traversal 0018 9033 CS 1 Segmented k-Space Traversal @@ -654,7 +653,7 @@ 0018 9076 SQ 1 Diffusion Gradient Direction Sequence 0018 9077 CS 1 Parallel Acquisition 0018 9078 CS 1 Parallel Acquisition Technique -0018 9079 TM 1-n Inversion Times +0018 9079 FD 1-n Inversion Times 0018 9080 ST 1 Metabolite Map Description 0018 9081 CS 1 Partial Fourier 0018 9082 FD 1 Effective Echo Time @@ -743,7 +742,7 @@ 0018 9311 FD 1 Spiral Pitch Factor 0018 9312 SQ 1 CT Geometry Sequence 0018 9313 FD 3 Data Collection Center (Patient) -0018 9314 SQ 1 CT Reconstruction Sequence +0018 9314 SQ 1 CT Reconstruction Sequence 0018 9315 CS 1 Reconstruction Algorithm 0018 9316 CS 1 Convolution Kernel Group 0018 9317 FD 2 Reconstruction Field of View @@ -763,7 +762,7 @@ 0018 9332 FD 1 Exposure in mAs 0018 9333 CS 1 Constant Volume Flag 0018 9334 CS 1 Fluoroscopy Flag -0018 9335 FD 1 Distance Source to Data Collection Center +0018 9335 FD 1 Distance Source to Data Collection Center 0018 9337 US 1 Contrast/Bolus Agent Number 0018 9338 SQ 1 Contrast/Bolus Ingredient Code Sequence 0018 9340 SQ 1 Contrast Administration Profile Sequence @@ -821,7 +820,7 @@ 0020 1206 IS 1 Number of Study Related Series 0020 1208 IS 1 Number of Study Related Instances 0020 1209 IS 1 Number of Series Related Instances -0020 3100 LO 1-n Source Image IDs (RET) +0020 3100 LO 1-n Source Image Ids (RET) 0020 3401 LO 1 Modifying Device ID (RET) 0020 3402 LO 1 Modified Image ID (RET) 0020 3403 DA 1 Modified Image Date (RET) @@ -860,30 +859,30 @@ 0022 0003 US 1 Image Path Filter Pass-Through Wavelength 0022 0004 US 2 Image Path Filter Pass Band 0022 0005 CS 1 Patient Eye Movement Commanded -0022 0006 SQ 1 Patient Eye Movement Command Code Sequence +0022 0006 SQ 1 Patient Eye Movement Command Code Sequence 0022 0007 FL 1 Spherical Lens Power -0022 0008 FL 1 Cylinder Lens Power +0022 0008 FL 1 Cylinder Lens Power 0022 0009 FL 1 Cylinder Axis -0022 000a FL 1 Emmetropic Magnification +0022 000a FL 1 Emmetropic Magnification 0022 000b FL 1 Intra Ocular Pressure -0022 000c FL 1 Horizontal Field of View +0022 000c FL 1 Horizontal Field of View 0022 000d CS 1 Pupil Dilated 0022 000e FL 1 Degree of Dilation 0022 0010 FL 1 Stereo Baseline Angle -0022 0011 FL 1 Stereo Baseline Displacement -0022 0012 FL 1 Stereo Horizontal Pixel Offset -0022 0013 FL 1 Stereo Vertical Pixel Offset +0022 0011 FL 1 Stereo Baseline Displacement +0022 0012 FL 1 Stereo Horizontal Pixel Offset +0022 0013 FL 1 Stereo Vertical Pixel Offset 0022 0014 FL 1 Stereo Rotation 0022 0015 SQ 1 Acquisition Device Type Code Sequence -0022 0016 SQ 1 Illumination Type Code Sequence +0022 0016 SQ 1 Illumination Type Code Sequence 0022 0017 SQ 1 Light Path Filter Type Stack Code Sequence 0022 0018 SQ 1 Image Path Filter Type Stack Code Sequence -0022 0019 SQ 1 Lenses Code Sequence -0022 001a SQ 1 Channel Description Code Sequence -0022 001b SQ 1 Refractive State Sequence -0022 001c SQ 1 Mydriatic Agent Code Sequence -0022 001d SQ 1 Relative Image Position Code Sequence -0022 0020 SQ 1 Stereo Pairs Sequence +0022 0019 SQ 1 Lenses Code Sequence +0022 001a SQ 1 Channel Description Code Sequence +0022 001b SQ 1 Refractive State Sequence +0022 001c SQ 1 Mydriatic Agent Code Sequence +0022 001d SQ 1 Relative Image Position Code Sequence +0022 0020 SQ 1 Stereo Pairs Sequence 0022 0021 SQ 1 Left Image Sequence 0022 0022 SQ 1 Right Image Sequence @@ -925,7 +924,7 @@ 0028 0300 CS 1 Quality Control Image 0028 0301 CS 1 Burned In Annotation 0028 1040 CS 1 Pixel Intensity Relationship -0028 1041 CS 1 Pixel Intensity Relationship Sign +0028 1041 SS 1 Pixel Intensity Relationship Sign 0028 1050 DS 1-n Window Center 0028 1051 DS 1-n Window Width 0028 1052 DS 1 Rescale Intercept @@ -978,7 +977,7 @@ 0028 9001 UL 1 Data Point Rows 0028 9002 UL 1 Data Point Columns 0028 9003 CS 1 Signal Domain Columns -0028 9099 US 1 Largest Monochrome Pixel Value +0028 9099 US 1 Largest Monochrome Pixel Value (RET) 0028 9108 CS 1 Data Representation 0028 9110 SQ 1 Pixel Measures Sequence 0028 9132 SQ 1 Frame VOI LUT Sequence @@ -1018,7 +1017,7 @@ 0038 0008 CS 1 Visit Status ID 0038 0010 LO 1 Admission ID 0038 0011 LO 1 Issuer of Admission ID -0038 0016 LO 1 Route of Admission +0038 0016 LO 1 Route of Admissions 0038 001a DA 1 Scheduled Admission Date 0038 001b TM 1 Scheduled Admission Time 0038 001c DA 1 Scheduled Discharge Date @@ -1049,7 +1048,7 @@ 003a 0208 SQ 1 Channel Source Sequence 003a 0209 SQ 1 Channel Source Modifiers Sequence 003a 020a SQ 1 Source Waveform Sequence -003a 020c SQ 1 Channel Derivation Description +003a 020c LO 1 Channel Derivation Description 003a 0210 DS 1 Channel Sensitivity 003a 0211 SQ 1 Channel Sensitivity Units Sequence 003a 0212 DS 1 Channel Sensitivity Correction Factor @@ -1076,7 +1075,7 @@ 0040 0007 LO 1 Scheduled Procedure Step Description 0040 0008 SQ 1 Scheduled Protocol Code Sequence 0040 0009 SH 1 Scheduled Procedure Step ID -0040 000a SH 1 Stage Code Sequence +0040 000a SQ 1 Stage Code Sequence 0040 000b SQ 1 Scheduled Performing Physician Identification Sequence 0040 0010 SH 1-n Scheduled Station Name 0040 0011 SH 1 Scheduled Procedure Step Location @@ -1110,7 +1109,7 @@ 0040 0303 US 1-2 Exposed Area 0040 0306 DS 1 Distance Source to Entrance 0040 0307 DS 1 Distance Source to Support (RET) -0040 030e DS 1 Exposure Dose Sequence +0040 030e SQ 1 Exposure Dose Sequence 0040 0310 ST 1 Comments on Radiation Dose 0040 0312 DS 1 X-Ray Output 0040 0314 DS 1 Half Value Layer @@ -1143,27 +1142,27 @@ 0040 1003 SH 1 Requested Procedure Priority 0040 1004 LO 1 Patient Transport Arrangements 0040 1005 LO 1 Requested Procedure Location -0040 1006 SH 1 Placer Order Number/Procedure (RET) -0040 1007 SH 1 Filler Order Number/Procedure (RET) +0040 1006 SH 1 Placer Order Number / Procedure (RET) +0040 1007 SH 1 Filler Order Number / Procedure (RET) 0040 1008 LO 1 Confidentiality Code 0040 1009 SH 1 Reporting Priority 0040 100a SQ 1 Reason for Requested Procedure Code Sequence 0040 1010 PN 1-n Names of Intended Recipients of Results -0040 1011 SQ 1 Intended Recipients of Results Identification Sequence +0040 1011 SQ 1 Intended Recipients of Results Identification Sequence 0040 1101 SQ 1 Person Identification Code Sequence 0040 1102 ST 1 Person's Address 0040 1103 LO 1-n Person's Telephone Numbers -0040 1400 LT 1 Requested Procedure Comments +0040 1400 LT 1 Requested Procedure Comments 0040 2001 LO 1 Reason for the Imaging Service Request (RET) 0040 2004 DA 1 Issue Date of Imaging Service Request 0040 2005 TM 1 Issue Time of Imaging Service Request -0040 2006 SH 1 Placer Order Number/Imaging Service Request (RET) -0040 2007 SH 1 Filler Order Number/Imaging Service Request (RET) +0040 2006 SH 1 Placer Order Number / Imaging Service Request (RET) +0040 2007 SH 1 Filler Order Number / Imaging Service Request (RET) 0040 2008 PN 1 Order Entered By 0040 2009 SH 1 Order Enterer's Location 0040 2010 SH 1 Order Callback Phone Number -0040 2016 LO 1 Placer Order Number/Imaging Service Request -0040 2017 LO 1 Filler Order Number/Imaging Service Request +0040 2016 LO 1 Placer Order Number / Imaging Service Request +0040 2017 LO 1 Filler Order Number / Imaging Service Request 0040 2400 LT 1 Imaging Service Request Comments 0040 3001 LO 1 Confidentiality Constraint on Patient Data Description 0040 4001 CS 1 General Purpose Scheduled Procedure Step Status @@ -1183,7 +1182,7 @@ 0040 4020 CS 1 Input Availability Flag 0040 4021 SQ 1 Input Information Sequence 0040 4022 SQ 1 Relevant Information Sequence -0040 4023 SQ 1 Referenced General Purpose Scheduled Procedure Steps Transaction UID +0040 4023 UI 1 Referenced General Purpose Scheduled Procedure Step Transaction UID 0040 4025 SQ 1 Scheduled Station Name Code Sequence 0040 4026 SQ 1 Scheduled Station Class Code Sequence 0040 4027 SQ 1 Scheduled Station Geographic Location Code Sequence @@ -1224,7 +1223,7 @@ 0040 a130 CS 1 Temporal Range Type 0040 a132 UL 1-n Referenced Sample Positions 0040 a136 US 1-n Referenced Frame Numbers -0040 a138 DS 1-n 1 Referenced Time Offsets +0040 a138 DS 1-n Referenced Time Offsets 0040 a13a DT 1-n Referenced Datetime 0040 a160 UT 1 Text Value 0040 a168 SQ 1 Concept Code Sequence @@ -1235,11 +1234,11 @@ 0040 a301 SQ 1 Numeric Value Qualifier Code Sequence 0040 a30a DS 1-n Numeric Value 0040 a360 SQ 1 Predecessor Documents Sequence -0040 a370 SS 1 Referenced Request Sequence +0040 a370 SQ 1 Referenced Request Sequence 0040 a372 SQ 1 Performed Procedure Code Sequence 0040 a375 SQ 1 Current Requested Procedure Evidence Sequence 0040 a385 SQ 1 Pertinent Other Evidence Sequence -0040 a491 CS 1 Completion Flag +0040 a491 CS 1 Completion Flag 0040 a492 LO 1 Completion Flag Description 0040 a493 CS 1 Verification Flag 0040 a504 SQ 1 Content Template Sequence @@ -1359,10 +1358,10 @@ 0070 0002 CS 1 Graphic Layer 0070 0003 CS 1 Bounding Box Annotation Units 0070 0004 CS 1 Anchor Point Annotation Units -0070 0005 CS 1 Graphic Annotation Units +0070 0005 CS 1 Graphic Annotation Units 0070 0006 ST 1 Unformatted Text Value -0070 0008 SQ 1 Text Object Sequence -0070 0009 SQ 1 Graphic Object Sequence +0070 0008 SQ 1 Text Object Sequence +0070 0009 SQ 1 Graphic Object Sequence 0070 0010 FL 2 Bounding Box Top Left Hand Corner 0070 0011 FL 2 Bounding Box Bottom Right Hand Corner 0070 0012 CS 1 Bounding Box Text Horizontal Justification @@ -1370,11 +1369,11 @@ 0070 0015 CS 1 Anchor Point Visibility 0070 0020 US 1 Graphic Dimensions 0070 0021 US 1 Number of Graphic Points -0070 0022 FL 2-n Graphic Data -0070 0023 CS 1 Graphic Type -0070 0024 CS 1 Graphic Filled -0070 0041 CS 1 Image Horizontal Flip -0070 0042 US 1 Image Rotation +0070 0022 FL 2-n Graphic Data +0070 0023 CS 1 Graphic Type +0070 0024 CS 1 Graphic Filled +0070 0041 CS 1 Image Horizontal Flip +0070 0042 US 1 Image Rotation 0070 0052 SL 2 Displayed Area Top Left Hand Corner 0070 0053 SL 2 Displayed Area Bottom Right Hand Corner 0070 005a SQ 1 Displayed Area Selection Sequence @@ -1391,7 +1390,7 @@ 0070 0100 CS 1 Presentation Size Mode 0070 0101 DS 2 Presentation Pixel Spacing 0070 0102 IS 2 Presentation Pixel Aspect Ratio -0070 0103 IS 1 Presentation Pixel Magnification Ratio +0070 0103 FL 1 Presentation Pixel Magnification Ratio 0070 0306 CS 1 Shape Type 0070 0308 SQ 1 Registration Sequence 0070 0309 SQ 1 Matrix Registration Sequence @@ -1426,7 +1425,7 @@ 0400 0000 UL 1 Group Length 0400 0005 US 1 MAC ID Number 0400 0010 UI 1 MAC Calculation Transfer Syntax UID -0400 0015 UI 1 MAC Algorithm +0400 0015 CS 1 MAC Algorithm 0400 0020 AT 1-n Data Elements Signed 0400 0100 UI 1 Digital Signature UID 0400 0105 DT 1 Digital Signature DateTime @@ -1515,7 +1514,7 @@ 2040 0060 CS 1 Overlay Magnification Type 2040 0070 CS 1 Overlay Smoothing Type 2040 0072 CS 1 Overlay or Image Magnification -2040 0074 CS 1 Magnify to Number of Columns +2040 0074 US 1 Magnify to Number of Columns 2040 0080 CS 1 Overlay Foreground Density 2040 0082 CS 1 Overlay Background Density 2040 0090 CS 1 Overlay Mode (RET) @@ -1535,15 +1534,15 @@ 2100 0050 TM 1 Creation Time 2100 0070 AE 1 Originator 2100 0140 AE 1 Destination AE -2100 0160 SH 1 Owner ID -2100 0170 IS 1 Number of Films +2100 0160 SH 1 Owner ID +2100 0170 IS 1 Number of Films 2100 0500 SQ 1 Referenced Print Job Sequence 2110 0000 UL 1 Group Length 2110 0010 CS 1 Printer Status 2110 0020 CS 1 Printer Status Info 2110 0030 LO 1 Printer Name -2110 0099 SH 1 Printer Queue ID +2110 0099 SH 1 Print Queue ID 2120 0010 CS 1 Queue Status 2120 0050 SQ 1 Print Job Description Sequence @@ -1560,6 +1559,7 @@ 2130 00a0 SQ 1 Proposed Study Sequence 2130 00c0 SQ 1 Original Image Sequence +2200 0000 UL 1 Group Length 2200 0001 CS 1 Label Using Information Extracted From Instances 2200 0002 UT 1 Label Text 2200 0003 CS 1 Label Style Selection @@ -1599,7 +1599,7 @@ 3002 0034 DS 4 Diaphragm Position 3002 0040 SQ 1 Fluence Map Sequence -3002 0041 CS 1 Fluence Data Source +3002 0041 CS 1 Fluence Data Source 3002 0042 DS 1 Fluence Data Scale 3004 0000 UL 1 DVH Group Length @@ -1609,12 +1609,12 @@ 3004 0006 LO 1 Dose Comment 3004 0008 DS 3 Normalization Point 3004 000a CS 1 Dose Summation Type -3004 000c DS 2-2n Grid Frame Offset Vector +3004 000c DS 2-n Grid Frame Offset Vector 3004 000e DS 1 Dose Grid Scaling 3004 0010 SQ 1 RT Dose ROI Sequence 3004 0012 DS 1 Dose Value 3004 0014 CS 1-3 Tissue Heterogeneity Correction -3004 0040 DS 1 DVH Normalization Point +3004 0040 DS 3 DVH Normalization Point 3004 0042 DS 1 DVH Normalization Dose Value 3004 0050 SQ 1 DVH Sequence 3004 0052 DS 1 DVH Dose Scaling @@ -1725,7 +1725,7 @@ 3008 0100 SQ 1 Recorded Source Sequence 3008 0105 LO 1 Source Serial Number 3008 0110 SQ 1 Treatment Session Application Setup Sequence -3008 0116 CS 1 Application Setup Check +3008 0116 CS 1 Application Setup Check 3008 0120 SQ 1 Recorded Brachy Accessory Device Sequence 3008 0122 IS 1 Referenced Brachy Accessory Device Number 3008 0130 SQ 1 Recorded Channel Sequence @@ -2295,8 +2295,8 @@ 6000 0000 UL 1 Group Length 6000 0010 US 1 Overlay Rows -6000 0011 US 1 Columns -6000 0012 US 1 Planes +6000 0011 US 1 Overlay Columns +6000 0012 US 1 Overlay Planes 6000 0015 IS 1 Number of Frames in Overlay 6000 0022 LO 1 Overlay Description 6000 0040 CS 1 Overlay Type @@ -2309,15 +2309,15 @@ 6000 0102 US 1 Overlay Bit Position 6000 0110 LT 1 Overlay Format (RET) 6000 0200 US 1 Overlay Location (RET) -6000 1001 US 1 Overlay Activation Layer +6000 1001 CS 1 Overlay Activation Layer 6000 1100 US 1 Overlay Descriptor - Gray (RET) 6000 1101 US 1 Overlay Descriptor - Red (RET) 6000 1102 US 1 Overlay Descriptor - Green (RET) 6000 1103 US 1 Overlay Descriptor - Blue (RET) -6000 1200 US 1-n Overlays - Gray -6000 1201 US 1-n Overlays - Red -6000 1202 US 1-n Overlays - Green -6000 1203 US 1-n Overlays - Blue +6000 1200 US 1-n Overlays - Gray (RET) +6000 1201 US 1-n Overlays - Red (RET) +6000 1202 US 1-n Overlays - Green (RET) +6000 1203 US 1-n Overlays - Blue (RET) 6000 1301 IS 1 ROI Area 6000 1302 DS 1 ROI Mean 6000 1303 DS 1 ROI Standard Deviation -- 2.45.1