]> Creatis software - gdcmData.git/commitdiff
cvs add -ko
authorjpr <jpr>
Tue, 20 Jan 2004 09:59:29 +0000 (09:59 +0000)
committerjpr <jpr>
Tue, 20 Jan 2004 09:59:29 +0000 (09:59 +0000)
to be sure they were uploaded in 'binary' mode

README [new file with mode: 0644]
checkWrite.sh
mr176621.dcm.acr [new file with mode: 0644]

diff --git a/README b/README
new file mode 100644 (file)
index 0000000..d4e6fa2
--- /dev/null
+++ b/README
@@ -0,0 +1,140 @@
+multiframe1.dcm
+multiframe2.dcm
+               Cardiovasculaire multiframe
+               True Dicom
+               Explicit VR
+               les champs prives ne *sont pas* Explicit VR
+               tous les Groupes comportent un element 0000
+               Pixels codes sur 10 bits
+               
+acusson.dcm
+               Echographie single Frame
+               True Dicom
+               Explicit VR
+               3 LUT (R, G, B)
+               
+irmPhlipsNew1.dcm
+               Irm Philips LyonSud
+               True Dicom
+               Explicit VR             
+               SQ curieuse en (0008,1140)
+               
+pixelNonRect.dcm
+               Irm Philips Marseille
+               True Dicom
+               Explicit VR     
+               les champs prives *sont* Explicit VR            
+               les champs prives contiennent des caract non imprimables 
+               Pixels non Rectangulaires       
+               
+esrf1.dcm
+               Vg Studio Max
+               True Dicom
+               Explicit VR     
+               Manque 'Samples Per Pixel' pour etre lue par e-film     
+               
+jpeg16Bits.dcm 
+               CT Siemens HEH
+               True Dicom
+               jpeg 16 Bits Lossy
+               (fait casser DcmRead 8/11/2002 :-(
+               repare 27/11
+       
+jpeglossles1.dcm
+               Jpeg LossLess
+               True Dicom
+               Explicit VR     
+               SQ en (0008,2112)       
+               contient peut etre (?!) des curiosités apres les Pixels 
+               
+jpeglossless2.dcm
+               CR Thoravision Philips Cardio
+               Jpeg LossLess
+               True Dicom
+               Explicit VR     
+               Jpeg mal decodé par les fonctions utilisees
+               
+jpeglossy1.dcm
+jpeglossy2.dcm
+jpeglossy3.dcm
+               Jpeg Lossy
+               Decodage non traite par mes fonctions
+               
+oldACR00001.ima
+               ACRNEMA V1 'ancien'
+               Groupe 20  NE contient  PAS Study et Serie Instance UID
+                               ET          Study ID et Series Number sont VIDES
+
+newACR1000.nema
+               ACRNEMA V2 'moderne'
+               Groupe 20 contient      Study    et Serie Instance UID
+                               ET      Study ID et Series Number
+                               
+imageEcat.ecat
+               Image au format ECAT (Medecine Nucleaire)
+               On n'y echapera pas encore tres longtemps, a celles la :-( 
+               
+---------------- Ajouts 20 Nov 2002
+
+mr176621
+               MR Toshiba
+               ACRNEMA-V2
+               abscence de l'element 0000 (group length) pour tous les groupes
+               
+cr_45031
+               CR Fuji
+               ACRNEMA V2
+               1670x2010
+               
+MR.6799.1
+               MR Pickert
+               DICOM V3 like
+               manque le 'file preamble' de 200 octets
+               
+cr172241
+               CR Kodak
+               ACRNEMA V2
+               (0028 3000): SQ
+               (fffe, e00d), (fffe,e0dd), apres (0028, 3006) !!!
+               
+US.1.2.dcm
+US.1.3.dcm
+               US ACUSON
+               DICOM 3 Multiframe
+               JPEG 8 bits Lossy
+               (0028,0002) Samples Per Pixel = 3
+               (0018, 6011) : SQ
+               les champs à l'interieur de cette 'Sequence'
+                       contiennent des caract non imprimables qui déconfigurent l'ecran :-(
+               
+               Ces deux examens, correspondant a 2 patients differents ont le meme Study ID
+               
+---------------- Ajouts 27/11/2002
+
+sonata.dcm
+               IRM Siemens Sonata (images taggees)
+               SQ en (0008,1140),contenant (0008,1150), (0008,1155) 3 fois 
+               
+               
+---------------- Ajouts 16/12/2002     
+icone.dcm
+       CT Picker
+       image 512x512
+       (28 200 )contient une icone de 64x64
+               --> DEUX groupes 7FE0 dans la même image
+
+----------------- Ajouts 13/02/2003
+
+sonata.nema
+       MR Siemens sonata
+       True DICOM
+       (18,1310) est un champ de Value Multiplicity > 1
+       vr : US mais longueur = 8
+
+--------------Ajouts 21/03/2003
+
+philipsMR-lossy.ima
+       MR Philips (Neuro)
+       True Dicom
+       indiquée comme ACR-NEMA V1 dans l'entete
+       JPEG Lossy (Transfer Syntax UID : [1.2.840.10008.1.2.4.51])
index f081257f1a190a937ca96fcc5c8a537f1b819760..cb1f380e4ab5bd2308f4ef4239e75eb12936ac79 100644 (file)
 
 #No Swap Info
 #------------
+affim filein=mr176621.dcm
+affimdcm filein=mr176621.dcm
+testWrite mr176621.dcm r
+affimdcm filein=mr176621.raw dim=512 nbit=16
 testWrite mr176621.dcm d
 affimdcm filein=mr176621.dcm.DCM  # xmedcon OK
 
diff --git a/mr176621.dcm.acr b/mr176621.dcm.acr
new file mode 100644 (file)
index 0000000..0ac91a3
Binary files /dev/null and b/mr176621.dcm.acr differ